Ericsson PBC6500 connection

RS connection to connect more than Ericsson PBC-6500 to each others and about login to Cabinet

Define Printer cable with printer to usb driver 
 Connect a USB cable between the USB interface on the SCU and a USB port in laptop. 
 confirm that laptop can read printer cable (right click on my computer then properties then device manager then ports (com&LPT )
 Open hyper terminals and change it connection properties as bellows : 
Bits per second 115200
Data bits 8
Parity None
Stop bits 1
Flow control None
after that open connection when Hyper terminal screen Press ESC and then write "restSCU" and enter after that you will find IP for cabinet , Subnet Mask and gateway after that use Ethernet cable to login to cabinet 
 for Example if cabinet IP 192.168.100.100
Make PC IP 192.168.100.99 or 101 
 open browser and type 192.168.100.100 
user name root and Password default

The following PDFs illustrate more about PBC6500

http://adf.ly/13664457/pbc6500