:How to unlock Data port of BaseBand 5216
It's clear that BB5216 come configured from Ericsson and just installed only
and connect the fiber cables from RRUs to it only
but some BB5216 come and it's configuration is not completed or wrong
if we run the TCU script on the TCU but the BB5216 data port not opened (port between BB5216
(and TCU
the first thinking about the problem is to replace the fiber connection between TCU and BB5216
but the problem may be not in the cable and may be in the configuration
(may be the data port of BB5216 (TNB
still not opened
:the following steps to check on the port
First login the BB using Element manager Luncher
after connected on the BB5216 write the following commands
get ethernetport=TN_B
This command will display all details about TN_B we will concerned on two points only
Administative state: locked or unlocked
Operational state:disabled or enabled
If Admin state is locked and Operational state is disabled then the TNB port is close
:to open it write the following command
deb ethernetport=TN_B
After that the port will be unlocked and enabled
للاستفسار عن اى نقطه غير واضحه لا تتردد فى السؤال
واذا واجهت اى مشكله اثناء التحميل ارجو التعليق
ولا تنسونا من الدعاء
وشكرا
0 التعليقات:
إرسال تعليق